HOBO Type Thermocouple Data Logger

HOBO UX100-014M Single Channel



HOBO UX100-014M Single Channel Data logor termokopel mencatat suhu di lingkungan dalam ruangan dengan sensor termokopel (dijual terpisah). Dirancang untuk berbagai aplikasi pemantauan - mulai dari pemantauan proses industri sampai uji kematangan beton - logger memberikan fleksibilitas luar biasa dengan menerima probe termokopel J, K, T, E, R, S, B atau N.




Fitur Utama
  • Pembacaan termokopel J tinggi, J, K, T, E, R, S, B, N.
  • Mudah untuk melihat tampilan LCDKapasitas memori yang besar.
  • Ambang alarm visual tinggi & rendah.
  • Mode logging New Burst and StatisticsCatat suhu sekitar dengan termistor internal.


Spesifikasi :

Thermocouple

TypeRangeAccuracyResolution
J-210° to 760°C (-346° to 1,400°F)±0.6°C (±1.08°F) ± thermocouple probe accuracy0.03°C (0.06°F)
K-260° to 1,370°C (-436° to 2,498°F)±0.7°C (±1.26°F) ± thermocouple probe accuracy0.04°C (0.07°F)
T-260° to 400°C (-436° to 752°F)±0.6°C (±1.08°F) ± thermocouple probe accuracy0.02°C (0.03°F)
E-260° to 950°C (-436° to 1,742°F)±0.6°C (±1.08°F) ± thermocouple probe accuracy0.03°C at (0.05°F)
R-50° to 1,550°C (-58° to 2,822°F)±2.2°C (±3.96°F) ± thermocouple probe accuracy0.08°C (0.15°F)
S-50° to 1,720°C (-58° to 3,128°F)±2.2°C (±3.96°F) ± thermocouple probe accuracy0.08°C (0.15°F)
B550° to 1,820°C (1,022° to 3,308°F)±2.5°C (±4.5°F) ± thermocouple probe accuracy0.1°C (0.18F)
N-260° to 1,300°C (-436° to 2,372°F)±1.0°C (±1.8°F) ± thermocouple probe accuracy0.06°C (0.11°F)

Internal 10K Thermistor (Temperature)

Range: Logging: -20° to 70°C (-4° to 158°F)
Accuracy: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), see Plot A
Resolution: 0.024°C at 25°C (0.04°F at 77°F); see Plot A
Drift: <0.1°C (0.18°F) per year


Logger

Logger Operating Range
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing); logger accuracy from 0° to 50°C (32° to 122°F)
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification
Resolution: 22-bit
Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging modes: Normal, Burst or Statistics
Memory modes: Wrap when Full or Stop when Full
Start modes: Immediately, Push Button, Date & Time or Next Interval
Stop modes: When Memory Full, Push Button, or Date & Time
Restart mode: Push Button
Time accuracy: ±1 minute per month at 25°C (77°F), see Plot B
Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater
Battery type: One 3V CR2032 lithium battery
Memory: 512 KB (208,076 measurements, maximum)
Download type: USB 2.0 interface
Full memory download time: 1 minute, 30 seconds
LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 3.66 x 5.94 x 1.52 cm (1.44 x 2.34 x 0.6 in.)
Weight: 30 g (1.06 oz)
Environmental rating: IP50

Share this

Related Posts

Previous
Next Post »

1 comments:

Write comments
10 April 2022 at 11:17 delete

Vint Ceramic Art | TITNIA & TECHNOLOGY
Explore an all new “Vint Ceramic goyangfc.com Art” project on TITNIA & wooricasinos.info TECHNOLOGY. Our team of sculptors and artists ventureberg.com/ have created dental implants new and

Reply
avatar